We manufacture equipment for a complete refrigeration and air conditioning lab, from basic vapour compression rigs to ice plant and cooling tower test rigs. We export from India. This page gives model codes for mechanical engineering departments and vocational centres in Egypt, Kenya, Ethiopia, Ghana and Tanzania.
Our refrigeration and air conditioning lab range
These products are from our Refrigeration & Air Conditioning Lab Equipment category.
| Product | Model code | What students determine |
|---|---|---|
| Vapour Compression Refrigeration System Test Rig | RLE-0013 | Refrigeration effect and coefficient of performance |
| Window Air Conditioner Test Rig | RLE-0014 | Performance of a window air conditioner |
| Heat Pump Test Rig | RLE-0009 | Heating and cooling performance of a heat pump |
| Ice Plant Test Rig | RLE-0003 | Capacity and performance of an ice plant |
| Water Cooling Tower Test Rig | RLE-0005 | Cooling tower range, approach and effectiveness |
| Vapor Absorption Refrigeration Cycle Test Rig | RLE-0012 | Operation of an absorption cycle |
| Recirculating Type Air Conditioning Test Rig | RLE-0011 | Psychrometric processes in a duct |
| Cascade Refrigeration Test Rig | RLE-0001 | Two-stage low-temperature refrigeration |
| RAC Components Cut Sections Display & Accessories | RLE-0007 | Construction of compressors, valves and controls |
Our product page for the window air conditioner test rig lists a hermetically sealed compressor of 1 ton cooling capacity, an air-cooled condenser of copper pipe with aluminium fins, a capillary tube expansion device, a single-phase 230 V AC, 15 A supply and a floor space of 2 m x 1 m.
Applications
- Degree and diploma courses in thermal engineering.
- Vocational training for refrigeration and air conditioning technicians.
- Demonstrations of energy use and efficiency.
| Topic | Rig |
|---|---|
| Basic cycle | Vapour compression test rig, refrigerator test rig |
| Air conditioning | Window AC rig, recirculating AC rig, air washer |
| Industrial cooling | Ice plant, cooling tower, cascade system |
| Heat recovery | Heat pump |
Features
- Working systems with real compressors, condensers and evaporators.
- Pressure gauges and temperature points around the cycle.
- Energy meters for compressor input.
- Cut sections that show the inside of components.
- Manuals with experiment procedures.
Refrigerant type and capacities vary by rig. We state them in the quotation and can discuss alternatives where a refrigerant is restricted in your country.
Choosing rigs for degree and vocational levels
Degree courses want measurement. Students calculate refrigeration effect, compressor work and coefficient of performance from readings around the cycle, then compare with theory. Test rigs with full instrumentation suit that purpose.
Vocational courses want skills: identifying components, charging, leak testing, fault finding and safe handling. Trainers with accessible components and cut sections serve that better than a densely instrumented rig.
Many institutions teach both. A sensible first order is one vapour compression test rig, one air conditioning rig, a set of cut sections and, for technician courses, service tools such as gauges, a vacuum pump and a recovery unit sourced to local regulations.
Markets served: import and site notes
Most rigs run on single-phase power. Larger plants may need three-phase. Check the supply and ventilation of the room.
| Country | Nominal mains supply | Usual port of entry | Note for this equipment |
|---|---|---|---|
| Egypt | 220 V, 50 Hz | Alexandria | Air conditioning is a major energy load. Courses stress efficiency measurement. |
| Kenya | 240 V, 50 Hz | Mombasa | Cold chains for flowers and vegetables create steady demand for refrigeration technicians. |
| Ethiopia | 220 V, 50 Hz | Djibouti, then road or rail (landlocked) | Growing cities need trained air conditioning installers. Vocational trainers fit that need. |
| Ghana | 230 V, 50 Hz | Tema | Fish and food cold stores depend on ice plants. An ice plant rig links directly to local industry. |
| Tanzania | 230 V, 50 Hz | Dar es Salaam | Coastal heat and humidity make psychrometry practical. Add the air conditioning duct rig. |
Why buy from us
- Manufacturer of test rigs and simpler trainers for both degree and vocational levels.
- Related heat transfer equipment available on the same order.
- Itemised offers for tender evaluation.
- Installation, commissioning and training offered.
How to order
- List the experiments or rigs you need.
- State voltage, frequency and any refrigerant restrictions.
- Give the destination port.
- We send a quotation and delivery schedule.
Reach us through the contact page. Each rig is built to order and priced on enquiry.
Frequently asked questions
Are rigs shipped charged with refrigerant?
Transport rules for refrigerants vary. We confirm in the offer whether a rig ships charged or is charged at installation.
Do you supply a laboratory humidifier or air washer?
An Evaporative Cooler Test Rig and an air washer test rig are listed. Tell us the experiment and we will match it.
What other energy equipment fits a thermal machine laboratory?
Engine test benches, compressors and steam rigs. See Thermal Engineering Lab Equipment and Heat and Mass Transfer Lab Equipment. Standard test equipment such as thermometers and clamp meters can be added.