Mass Transfer Lab Equipment
Chemical engineering departments searching for mass transfer lab equipment manufacturers in India need glass and stainless steel columns that run safely. Civil Mechanical India is among the suppliers in India of six bench units that teach distillation, absorption, extraction and equilibrium.
Mass transfer operations are the heart of a chemical engineering lab, and these units cover the standard list. The packed bed distillation column separates a liquid mixture by boiling and condensing, and the packed column gas absorption unit contacts gas and liquid to remove a component. The liquid-liquid extraction column uses two immiscible liquids, and the wetted wall column measures mass transfer coefficients.
The vapour liquid equilibrium apparatus gives data for phase diagrams, and the ion exchange set separates ions with resin columns. Units usually have heaters, pumps, rotameters and sampling ports, so students can calculate efficiency, HETP or transfer units. Check column height, packing, heater power and analysis method, such as refractometer or titration.
Last updated: November 2026
Liquid Liquid Extraction Column Unit
Product code: CMI-NP-1520Buy Liquid Liquid Extraction Column Unit from India
Liquid Liquid Extraction Column Unit is a pulsed or packed glass extraction column with two feed tanks and pumps for contacting two immiscible liquids. It is used for studying liquid-liquid extraction, stage efficiency and flooding behaviour.
Packed Bed Distillation Column Unit
Product code: CMI-NP-1521Buy Packed Bed Distillation Column Unit from India
Packed Bed Distillation Column Unit is a laboratory glass packed distillation column with a heated reboiler, reflux condenser and temperature indicators. It is used for studying batch distillation, separation efficiency and HETP of a binary mixture.
Packed Column Gas Absorption Unit
Product code: CMI-NP-1522Buy Packed Column Gas Absorption Unit from India
Packed Column Gas Absorption Unit is a bench-top glass packed column with a gas blower, water circuit and rotameters for studying absorption of a soluble gas into a liquid. It is used for determining mass transfer coefficients and HTU/NTU of packed columns.
Vapour Liquid Equilibrium Apparatus
Product code: CMI-NP-1523Buy Vapour Liquid Equilibrium Apparatus from India
Vapour Liquid Equilibrium Apparatus is a glass Othmer-type recirculating still with heater and condenser for finding vapour-liquid equilibrium of binary mixtures. It is used for plotting equilibrium curves and checking activity coefficients.
Wetted Wall Column Mass Transfer Apparatus
Product code: CMI-NP-1524Buy Wetted Wall Column Mass Transfer Apparatus from India
Wetted Wall Column Mass Transfer Apparatus is a vertical glass tube apparatus in which a liquid film flows down the wall while gas flows counter-current. It is used for measuring gas-liquid mass transfer coefficient in a wetted wall column.
Mass Transfer Lab Equipment range by function
| Function | Products | What to confirm |
|---|---|---|
| Distillation and equilibrium | Packed Bed Distillation Column Unit, Vapour Liquid Equilibrium Apparatus | Column diameter and packing height, reboiler power, condenser type, reflux control and sampling ports. |
| Absorption and wetted wall | Packed Column Gas Absorption Unit, Wetted Wall Column Mass Transfer Apparatus | Gas and liquid flow ranges, air compressor or blower, column dimensions and pressure drop measurement. |
| Extraction and ion exchange | Liquid Liquid Extraction Column Unit, ION Exchange | Column type (pulsed or packed), pump flow, resin quantity, and number of sampling points. |
How is this different from Adsorption in Packed Bed?
Adsorption in a packed bed is one specific mass transfer operation, studied with six dedicated units such as fixed bed, isotherm and kinetics apparatus. This page covers the wider set of operations, namely distillation, absorption, extraction, equilibrium and ion exchange. If a department is building a full mass transfer lab, begin here and add the adsorption page for detail.
See also: Adsorption in Packed Bed
Full Mass Transfer Lab Equipment product list
The complete Mass Transfer Lab Equipment range (6 products), in alphabetical order:
| ION Exchange | Liquid Liquid Extraction Column Unit | Packed Bed Distillation Column Unit |
| Packed Column Gas Absorption Unit | Vapour Liquid Equilibrium Apparatus | Wetted Wall Column Mass Transfer Apparatus |
Specifications and standards
What should be checked before ordering mass transfer lab equipment?
Match each unit to an experiment on your syllabus, then check column dimensions, packing type, heater and pump ratings and flow meter ranges. Confirm glass or stainless steel construction and the analysis method needed, such as refractometer, titration or gas chromatography. Ask for the supply (230 V or 415 V), cooling water need and any control panel features.
What is HETP in a packed distillation column?
Height equivalent to a theoretical plate is the packed height that gives the separation of one ideal stage. Students find it by measuring compositions along the column, so a lower HETP indicates a more efficient packing.
Who buys Mass Transfer Lab Equipment?
Chemical engineering, petrochemical, pharmaceutical and food technology departments, polytechnic chemical courses and research groups buy these units. A normal order covers distillation, absorption, extraction and equilibrium apparatus, so a batch of thirty students can do one unit operation experiment each lab turn.
Related ranges
Frequently asked questions
Are the columns made of glass?
Many bench units use borosilicate glass columns so that students can observe flow, while larger units use stainless steel. State your preference and safety requirements in the enquiry.
Do you supply across India?
Civil Mechanical India supplies mass transfer units across India with safe packing for glass parts. Provide your delivery city and tender details.
Can you export these units?
Export orders are crated with manuals and electrical supply configured for your country. Specify destination and mains standard when you enquire.
Is installation support available?
We can guide installation, water and power connections and commissioning of the column units. Provide the room details and utilities so the quotation includes the scope.
What does a vapour liquid equilibrium apparatus show?
It shows the composition of liquid and vapour in equilibrium at given temperature and pressure, which students plot as a T-x-y diagram. This data is essential for designing distillation columns.
Request a tender quotation
We are leading manufacturers and suppliers for tender requirements from India, serving civil laboratory and industrial testing tenders and supplying mechanical engineering and testing laboratory equipment in bulk and on OEM terms. Send us your tender specifications, and a complete quotation for Mass Transfer Lab Equipment will be prepared accordingly.
- Civil laboratory & industrial testing tenders
- Mechanical engineering & testing lab equipment
- Bulk and OEM supply