Panel For Testing Of Buchloz Relay Setup
Product code: EES0001Buy Panel For Testing Of Buchloz Relay Setup from India
Panel For Testing Of Buchloz Relay Setup
Protection labs depend on setups where a fault can be created safely and the relay response observed. Civil Mechanical India is among the Electrical Drive Lab Equipment manufacturers in India listing relay test panels, and a supplier in India of transformer protection and oil testing sets that follow common utility practice.
Transformer protection is handled by a Buchholz relay test panel, a percentage biased differential relay setup with digital ammeters for differential and through currents, and a transformer oil set. The oil tester is manual or motorised, takes a single phase 220 V input and gives an output of 0 to 60 kV or 100 kV with a set breakdown voltage.
Feeder and voltage protection includes an IDMT and directional overcurrent relay setup, where students plot the time against current curve and observe directional action, and an under and over voltage relay setup. The DC motor speed control trainer adds a simple drive experiment with armature and field control, giving the department an introductory drive exercise alongside the relay panels.
Last updated: November 2026
Panel For Testing Of Buchloz Relay Setup
Percentage Biased Differential Relay
IDMT And Directional Over Current Relay Setup
Under And Over Voltage Relay Setup
A trainer to control the speed of a DC motor by armature voltage and field control. Used in electrical drives labs. Features include armature and field control, thyristor converter and speed and current meters.
| Function | Products | What to confirm |
|---|---|---|
| Transformer protection | Panel For Testing Of Buchloz Relay Setup, Percentage Biased Differential Relay, Transformer Oil Set | Relay type and settings range, transformer rating, test voltage for oil, and safety interlocks and meters provided. |
| Feeder and voltage protection | IDMT And Directional Over Current Relay Setup, Under And Over Voltage Relay Setup | Relay characteristics (IDMT curves, time multiplier), CT and PT ratios, trip indication and supply requirements. |
| Drive control | DC Motor Speed Control Trainer | Motor rating, controller type, armature and field control range and meters supplied. |
Power electronics equipment is about converters, SCR firing circuits and motor controllers. The relay and protection panels here deal with detecting faults in transformers, feeders and voltage excursions, and with insulation testing of oil. One teaches how to control and convert power, the other teaches how to guard the power system.
See also: Electrical Machine Power Electronics Lab Equipment
The complete Electrical Drive Lab Equipment range (6 products), in alphabetical order:
Ask the relay type and its pickup range, time multiplier setting, rated current and voltage, and whether the panel includes a fault simulation source. For IDMT relays, check the characteristic curve (normal, very or extremely inverse) and the number of current and voltage inputs.
Give the maximum test voltage, 60 kV or 100 kV, the electrode gap (2.5 mm as per IS 335), the rate of voltage rise and whether you need manual or motorised control. Check the test cell, stirring arrangement and the safety interlock on the high voltage enclosure.
Most panels run from 230 V single phase mains with built-in transformers and variable autotransformers to set the fault current. Confirm that fuses, MCBs and earthing terminals are fitted, as these panels carry high currents at low voltage and need protection.
Power systems and electrical protection laboratories in engineering colleges and polytechnics buy relay panels. Utility training schools use them to show differential and Buchholz protection, and transformer maintenance workshops buy oil breakdown sets for dielectric strength testing. The DC drive trainer is also included in electrical drives practicals together with a motor and rheostat.
It detects gas accumulation or oil surge inside an oil-filled transformer, caused by incipient faults such as insulation failure, and signals an alarm or trip. The panel simulates the float and surge elements.
The bias coil raises the operating threshold with through current, avoiding false trips from CT mismatch during external faults, while still operating on internal faults.
New oil generally withstands 50 kV or more for a 2.5 mm gap, while service oil below about 30 kV needs filtration. The set shows the breakdown reading.
It provides separate controls for armature voltage and field current, giving speed control below and above base speed. A tachometer shows the resulting speed.
Send the tender specification and the destination supply frequency so that the relays, meters and transformers match the buyer's practice, and we will return a technical compliance statement.
We are leading manufacturers and suppliers for tender requirements from India, serving civil laboratory and industrial testing tenders and supplying mechanical engineering and testing laboratory equipment in bulk and on OEM terms. Send us your tender specifications, and a complete quotation for Electrical Drive Lab Equipment will be prepared accordingly.
Send us your equipment list or tender specification. We quote against IS, BS, EN, ASTM and AASHTO standards and ship to 90+ countries.