Kjeldahl Distillation Digestion Unit
Product code: CIVIL-KJU-189-0001Buy Kjeldahl Distillation Digestion Unit from India
Kjeldahl Distillation Digestion Unit
Labs that already own Kjeldahl glassware and need the heating and fume side search for Kjeldahl digestion unit manufacturers in India. Civil Mechanical India is among the suppliers in India who supply digital block digesters, six place heaters, steam generators and acid fume scrubbers separately.
Digestion is the hot, corrosive stage of the Kjeldahl method, so this range focuses on heaters and fume control rather than glass. A Kjeldahl distillation digestion unit has two mantle type heating platforms, one for digestion and one for distillation, while a digital controlled digestion unit uses an aluminium block with programmable temperature.
A six place digestion heater has individual controls and a fume system. Supporting items include a fume extraction manifold with tube caps and a water aspirator, a compact fume scrubber that neutralises acid vapours before release, and a standalone electric steam generator for distillation with level control. Glass parts are excluded so buyers can match their existing tubes and flasks.
Last updated: November 2026
Kjeldahl Distillation Digestion Unit
A Kjeldahl digestion unit using an aluminium block with digital temperature control, supplied without glass tubes for flexible use with standard 250 ml digestion tubes.
A fume extraction manifold with tube caps and a water aspirator or scrubber for removing acid fumes during Kjeldahl digestion and other acid digestions.
A compact scrubber unit that neutralises acid fumes from Kjeldahl digestion by water circulation and alkali, protecting laboratory ducts and users.
A standalone electric steam generator for Kjeldahl distillation with level control and safety valve, supplied without glass parts for use with existing distillation heads.
A six place Kjeldahl digestion heater with individual controls and fume manifold connection, used to digest protein samples in concentrated sulphuric acid before distillation.
| Function | Products | What to confirm |
|---|---|---|
| Digestion heating | Kjeldahl Digestion Unit with Digital Control, Six Place Kjeldahl Digestion Heater, Kjeldahl Distillation Digestion Unit | Number of places, tube size, maximum temperature, heater type (block or mantle) and individual control. |
| Fume control | Kjeldahl Fume Extraction Manifold Unit, Kjeldahl Fume Scrubber Neutralising Unit | Acid resistance of manifold material, aspirator or pump capacity, scrubber liquid and number of tubes served. |
| Steam supply | Kjeldahl Steam Generator Unit | Steam output, water level safety cutoff, heating power and compatibility with your distillation glass. |
The Kjeldahl Distillation Unit page centres on the whole distilling system with its glass flasks and condensers, in manual and automatic forms. This page covers the equipment around digestion: block heaters, fume manifolds, scrubbers and steam generators, supplied without glass. Labs expanding or replacing a heating block or fume system choose this page, and labs buying a full set start with distillation.
See also: Kjeldahl Distillation Unit
The complete Kjeldahl Digestion Unit range (6 products), in alphabetical order:
Confirm tube dimensions and the number of positions, then the maximum temperature, which should reach about 400 deg C for Kjeldahl. Check block material, individual versus common control, over temperature cutout and fume handling. Ask whether the manifold is acid resistant, what suction it needs, and whether supply is 230 V.
Digestion releases sulphur oxide and acid vapours. A water aspirator alone sends them into drains, while a scrubber neutralises them, protecting plumbing, staff and the environment. If you digest many samples daily, a scrubber is recommended and may be required by safety norms.
Food, dairy and feed testing laboratories, soil and fertiliser analysis centres, agriculture and veterinary universities, chemistry colleges and government quality control labs buy Kjeldahl digestion equipment. It is ordered with fume hoods, distillation systems and titration glassware, and tenders may split heating and glass into separate line items.
Many labs already own Kjeldahl tubes and flasks, so the units are sold without glass to cut cost and avoid breakage in transit. Glassware can be added if you need it.
Digestion generally needs about 350 to 420 deg C depending on the catalyst and sample, with the block held there until the liquid turns clear. Confirm your method when ordering so that the heater reaches it.
Fume manifolds are made for specific tube sizes and spacing, so share the dimensions of your heater and tubes. A wrong fit lets acid vapour leak into the room instead of reaching the aspirator or scrubber.
It supplies steam for the distillation step that follows digestion, so a lab can build a Kjeldahl line in stages from separate heater, manifold and steam parts rather than buying a complete system at once.
We supply across India and overseas with voltage, number of places and packing confirmed in the quotation. Send the tube size and daily sample count.
Civil Mechanical India is an established manufacturer and supplier for tender requirements from India, handling civil laboratory and industrial testing tenders and bulk and OEM orders for mechanical engineering and testing laboratory equipment. On receipt of your tender specifications, we will submit a complete quotation for Kjeldahl Digestion Unit.
Send us your equipment list or tender specification. We quote against IS, BS, EN, ASTM and AASHTO standards and ship to 90+ countries.