Soxhlet Extraction Units
Product code: ANL-SOX-0001Buy Soxhlet Extraction Units from India
Soxhlet Extraction Units
Fat and oil content is a routine test in food, feed and pharma labs. Soxhlet extraction unit manufacturers in India must supply both the heating base and the glassware, and as suppliers in India we offer mild steel and digital heated units, mantle based apparatus and complete single Soxhlet glass assemblies.
The range runs from teaching to routine testing. A single Soxhlet extractor glass assembly of 250 ml with flask, extractor and condenser is the simplest set, suited to demonstration and small solvent extraction. For batch work, the digital four place unit with temperature controlled heating and the six place apparatus with heating mantles run several samples in parallel.
The standard Soxhlet extraction unit has a mild steel body with stove enamel finish and chrome plated fittings. At the top end, the automatic Soxhlet fat analyser follows immersion, rinsing and solvent recovery steps to cut operator time and solvent use. Consumables such as cellulose thimbles with glass beads and spare joints keep the units running.
Last updated: November 2026
Soxhlet Extraction Units
An automatic solvent extraction unit with immersion, rinsing and solvent recovery steps for crude fat analysis, reducing time and solvent use compared with classic Soxhlet.
A four place digital Soxhlet extraction unit with temperature controlled heating for fat extraction, with precise heat and a compact stainless steel frame.
A single Soxhlet extractor glass set with flask, extractor and condenser for demonstration and small scale solvent extraction in teaching laboratories.
A six place Soxhlet extraction apparatus with heating mantles, extractors and condensers for fat and oil determination in food, feed and seed samples.
A set of cellulose extraction thimbles with glass beads, support and spare glass joints for Soxhlet units, used to continue regular fat and oil extraction work.
| Function | Products | What to confirm |
|---|---|---|
| Teaching and small scale extraction | Single Soxhlet Extractor Glass Assembly 250 ml, Soxhlet Extraction Units | Extractor volume, flask size, glass joint size, condenser type and stand arrangement. |
| Multi place batch extraction | Digital Soxhlet Extraction Unit 4 Place, Six Place Soxhlet Extraction Apparatus with Mantles | Number of places, heater type and wattage, temperature control accuracy and cooling water requirement. |
| Automatic fat analysis | Automatic Soxhlet Fat Analyser | Number of samples, extraction steps, solvent recovery rate, safety interlocks and solvent compatibility. |
| Thimbles and accessories | Soxhlet Extraction Thimble and Accessory Set | Thimble size and quantity, glass bead type and spare joint sizes to match the extractor. |
A Soxhlet unit repeatedly washes a solid sample with condensed solvent vapour to extract fat or oil, so it includes a heating source, glass extractor and condenser with cooling water. A water bath simply holds liquid at a set temperature for incubation or warming. Both can heat solvent flasks gently, but flammable solvents such as petroleum ether are normally extracted with a heating mantle or a purpose-built Soxhlet unit, not an open flame or a general bath.
See also: Water Baths
The complete Soxhlet Extraction Unit range (6 products), in alphabetical order:
Confirm the number of samples per run, extractor volume (often 150 to 250 ml), flask size and solvent type. Check heater wattage and whether control is analog or digital, glass joint standard, and whether mantles are included. Ask for cooling water needs, 230 V supply, spare glassware and thimbles. Methods such as AOAC or IS fat tests name the solvent and extraction time.
A manual four or six place unit is economical and flexible for several samples if an operator is present. An automatic fat analyser automates immersion, rinsing and solvent recovery, saving time and solvent for busy food and feed labs. Choose by daily sample volume and by how much solvent recovery matters.
Food technology and dairy labs, animal feed and oilseed testing labs, pharmaceutical and herbal extraction labs, university chemistry departments and agricultural research stations buy Soxhlet units. Orders usually combine them with analytical balances, hot air ovens for drying thimbles, desiccators and a water still, so we quote the full fat analysis bench together.
It extracts fat, oil or other soluble components from a solid sample by repeatedly percolating hot solvent through it. It is widely used for crude fat in food, feed and oilseeds.
Petroleum ether and hexane are common for fat determination. As they are flammable, use a heating mantle or enclosed heater, good ventilation and cooling water, and follow your lab safety rules.
Yes, we manufacture and supply Soxhlet extraction units across India for institutional tenders and ship overseas. Share the specification and quantity and we send a detailed quotation.
Conventional Soxhlet extraction takes several hours, commonly four to sixteen depending on the method. Automatic fat analysers shorten the cycle by combining immersion and rinsing steps.
Yes, extractors, condensers, flasks, thimbles and joints can be supplied separately. Quote the joint size of your existing glassware to get matching spares. Mention the extractor capacity as well.
We are leading manufacturers and suppliers for tender requirements from India, serving civil laboratory and industrial testing tenders and supplying mechanical engineering and testing laboratory equipment in bulk and on OEM terms. Send us your tender specifications, and a complete quotation for Soxhlet Extraction Unit will be prepared accordingly.
Send us your equipment list or tender specification. We quote against IS, BS, EN, ASTM and AASHTO standards and ship to 90+ countries.