Electrical machines and drives lab equipment manufacturers in India are judged by how many standard university experiments one bench can run. Our test sets pair each machine with a loading rheostat or brake dynamometer and meters, so students can plot characteristics instead of just reading a dial. Among suppliers in India we state machine kW and supply in each quotation.
A machines laboratory follows the syllabus order. The DC shunt motor and generator set covers load tests, speed control by field and armature methods, and generator characteristics. The single phase induction motor trainer deals with capacitor start and split phase starting, and the three phase set uses a squirrel cage motor with a brake dynamometer for no-load, blocked-rotor and load tests, from which the circle diagram and torque-slip curve are drawn.
The synchronous alternator panel with a prime mover and synchronising lamps covers open circuit and short circuit tests, regulation and parallel operation. A percentage biased differential relay unit shows how transformers and machines are protected, using digital ammeters for differential and through current. The transformer oil set raises voltage until the oil breaks down, which brings insulation testing into the same lab.
Last updated: November 2026
Transformer Oil Set
Percentage Biased Differential Relay
Test set with a DC shunt machine coupled to a loading rheostat and meters for load tests, speed control and characteristic studies of DC motors and generators.
Trainer with capacitor start and split phase motors on a base with meters and a load for studying starting methods and performance of single-phase motors.
Panel with a three-phase alternator, prime mover and synchronising lamps for studying OC and SC tests, regulation and parallel operation. Key highlights include alternator with DC prime mover and synchronising lamps and synchroscope.
Test set with a squirrel cage induction motor, brake dynamometer and meters for no load, blocked rotor and load tests to draw performance curves. Key highlights include induction motor with brake drum and spring balance dynamometer.
| Function | Products | What to confirm |
|---|---|---|
| DC and AC motor testing | DC Shunt Motor and Generator Test Set, Single Phase Induction Motor Trainer, Three Phase Induction Motor Load Test Set | Machine rating in kW or HP, rated voltage and speed, loading method, meter ranges and accuracy class |
| Alternator and protection | Synchronous Alternator Test and Synchronisation Panel, Percentage Biased Differential Relay | Alternator kVA, prime mover type, synchronising lamps or synchroscope, relay bias settings and fault simulation |
| Transformer oil testing | Transformer Oil Set | Maximum output kV, manual or motorised voltage rise, electrode gap, 1 phase 220 V input |
Machines and drives equipment works at ordinary supply levels, 230 V or 415 V, on rotating machines and protection relays, and the students' output is characteristic curves. High voltage equipment deals with kilovolts, insulation breakdown, impulse waveforms and spark gaps, and needs a protected room and earthing arrangement. The transformer oil set is the one item that sits at the boundary of both labs.
See also: High Voltage Lab Equipment
The complete Electrical Machines and Drives Lab Equipment range (6 products), in alphabetical order:
Confirm machine ratings, typically fractional to a few kW for teaching, rated voltage and the supply, whether 415 V three phase is available with an MCB. Check how loading is done (rheostat, brake drum or dynamometer), the meters and their class, and protection fitted. Ask that the offer list the experiments covered, with terminal diagrams and name plate data.
The alternator is driven by a prime mover, usually a DC motor or induction motor, and is loaded after open and short circuit tests. Synchronisation uses lamps or a synchroscope to bring it parallel with the supply. Ensure that the lab has adequate three phase supply, a stable foundation and a safe floor layout around the rotating set.
Electrical engineering colleges and polytechnics buy these sets for the machines and power systems laboratories, one set per batch bench. Technical universities add the relay and transformer oil sets for protection and high voltage topics, and industrial training centres use the induction motor and alternator panels for maintenance courses.
It records input power, speed, current and torque from a brake dynamometer at no load, blocked rotor and various loads, so that students can plot efficiency, slip, power factor and torque against output.
It compares currents entering and leaving a protected transformer or machine, with a bias that prevents false trips on through faults. The trainer shows how an internal fault produces a differential current that operates the relay.
The speed and excitation are adjusted until the voltage, frequency and phase sequence match the bus, as shown by synchronising lamps. Only then is the breaker closed, so students learn the conditions for parallel operation.
A sample of oil is placed between standard electrodes and voltage is raised until it breaks down. The breakdown voltage shows moisture and contamination, and low values mean the oil needs filtering or replacement.
Yes, we respond to Indian tender specifications for machine labs and ship abroad too. State the supply voltage and frequency, as machine windings differ for 50 Hz and 60 Hz.
Civil Mechanical India is an established manufacturer and supplier for tender requirements from India, handling civil laboratory and industrial testing tenders and bulk and OEM orders for mechanical engineering and testing laboratory equipment. On receipt of your tender specifications, we will submit a complete quotation for Electrical Machines and Drives Lab Equipment.
Send us your equipment list or tender specification. We quote against IS, BS, EN, ASTM and AASHTO standards and ship to 90+ countries.