Electric Loads Lab Equipment
No generator or transformer test is complete without a load that can be stepped up smoothly and carries the heat. Civil Mechanical India is one of the Electrical Load Lab Equipment manufacturers in India, and the suppliers in India who build resistive, inductive and capacitive banks that mount on a trolley or bench.
Resistive loads use heating elements or rheostats with step switches, and are made in single phase and three phase star-connected versions for alternators and transformers. A rheostatic load bank loads generators and supplies in steps, and a variable resistive panel offers continuously adjustable resistance for motor and generator experiments.
Reactive loads let students test power factor. The inductive load works on an air gap variation principle, with silicon steel stampings fitted in a trolley, and the capacitive load uses single phase ISI marked capacitors connected in star with discharge resistors, switched in steps with a rotary switch. Combined, they allow lagging and leading power factor tests on alternators and transformers.
Last updated: November 2026
Rheostatic Load Bank
Product code: CMI-NP-0267Buy Rheostatic Load Bank from India
A bank of resistive elements with step switches used for loading generators, transformers and supplies in the electrical lab. Used for load tests. Features include step wise load control, heavy duty resistors and ventilated MS enclosure.
Three Phase Resistive Load
Product code: CMI-NP-0268Buy Three Phase Resistive Load from India
A three phase star connected resistive load for testing alternators and transformers. Used in electrical machines labs. Features include balanced three phase load, step switches and heavy resistors.
Variable Resistive Load Panel
Product code: CMI-NP-0269Buy Variable Resistive Load Panel from India
A panel with variable power rheostats for adjusting loads on machines. Used in motor and generator experiments. Features include continuously variable resistance, wire wound rheostats and insulated knobs.
Electrical Load Lab Equipment range by function
| Function | Products | What to confirm |
|---|---|---|
| Resistive loads | Resistive Load, Three Phase Resistive Load, Rheostatic Load Bank, Variable Resistive Load Panel | kW rating and voltage, number of steps, star or single phase connection, cooling method and cable terminals. |
| Reactive loads | Inductive Load, Capacitive Load | kVAR rating, steps, air gap or tapped design, capacitor quality and discharge resistors, and single or three phase. |
How is this different from electric motors lab equipment?
Electric motors lab equipment is the machine under test, while electrical loads are what the machine drives or feeds. A generator experiment needs a resistive or reactive load bank, and a motor test needs a brake or generator loading. They are bought together so that load, power and efficiency can be measured.
See also: Electric Motors Lab Equipment
Full Electrical Load Lab Equipment product list
The complete Electrical Load Lab Equipment range (6 products), in alphabetical order:
| Capacitive Load | Inductive Load | Resistive Load |
| Rheostatic Load Bank | Three Phase Resistive Load | Variable Resistive Load Panel |
Specifications and standards
How should I choose the power rating of a load bank?
Match the load to the largest machine in the lab and add 25 percent headroom. For a 5 kVA alternator, a 5 kW three phase resistive bank in steps of 0.5 kW is typical. Check the continuous rating, cooling method and the voltage rating, for example 415 V three phase.
What details matter for inductive and capacitive loads?
For the inductive load, check the current range, the tapped steps and the winding insulation class. For capacitive loads, check the capacitor kVAR steps, voltage rating, discharge resistors and whether the capacitors are ISI marked. Both need a robust rotary or step switch for safe operation.
Which safety features should be in the order?
Ask for fuse or MCB protection, an indicator lamp for each step, earthing terminals, a mesh guard over heating elements and discharge resistors on capacitor banks. A wheeled trolley with locking casters also helps in moving a heavy bank safely around the lab.
Who buys Electrical Load Lab Equipment?
Electrical machines laboratories in engineering colleges and polytechnics buy load banks with every alternator, DC generator and transformer test set. Service workshops and small factories use them to test generators and rewound machines before returning them to the field. Research teams use reactive loads to study power factor correction, usually alongside metering panels and supply panels.
Related ranges
Frequently asked questions
Why does a resistive bank have both single and three phase versions?
Single phase banks suit small machines and DC tests, while three phase star connected banks balance the load on alternators and three phase transformers. Choose according to the machines in your lab.
What does the capacitive load do in an experiment?
It supplies leading reactive current, improving power factor in tests or showing how an alternator behaves with a leading load. The steps change in kVAR.
How is heat handled in a high-power rheostatic load?
Heating elements are mounted in a ventilated frame, often with forced air for higher loads. Check the duty cycle and the time for which the bank may run continuously.
Can the variable resistive panel replace a rheostat?
Yes for most experiments. It gives smooth control and carries more current than a small rheostat, but verify the current rating for the machines you plan to load.
Do you supply load banks for tenders?
Send the tender clause with the rating, voltage and number of steps required, and we will quote with drawings and a data sheet that can be matched line by line to the specification.
Request a tender quotation
Civil Mechanical India is one of the leading manufacturers and suppliers in India for tender requirements, covering civil laboratory and industrial testing tenders and the bulk and OEM supply of mechanical engineering and testing laboratory equipment. Kindly share your tender specifications and we shall submit a complete quotation for Electrical Load Lab Equipment.
- Civil laboratory & industrial testing tenders
- Mechanical engineering & testing lab equipment