Fumigation Chamber
Product code: CIVIL-FUM-192-0001Buy Fumigation Chamber from India
Fumigation Chamber
Microbiology and agriculture labs looking for laboratory fumigation chamber manufacturers in India need airtight construction and safe fumigant handling. Civil Mechanical India is among the suppliers in India offering formaldehyde cabinets, ozone chambers, interlocked pass boxes and portable formalin vaporisers.
The range starts with a general fumigation chamber built like a laboratory oven for drying and treating samples. A sealed stainless steel formaldehyde fumigation cabinet carries a vaporiser that releases fumigant over a timed cycle. A fumigation pass box with UV and interlocked doors transfers materials into clean rooms while keeping the clean side sealed.
An ozone fumigation chamber uses an ozone generator to disinfect instruments, and a portable formalin fumigator vaporiser heats formalin for room use. For agriculture and museums, a stored grain insect fumigation chamber is gas-tight and suited to treating grain, seed and herbarium specimens. Exhaust or neutralisation arrangements are an important selection point.
Last updated: November 2026
Fumigation Chamber
A sealed stainless steel fumigation cabinet with formaldehyde vaporiser and exhaust for disinfecting instruments, glassware and small items in microbiology and animal houses.
A fumigation pass box with interlocked doors and UV germicidal lamp for transferring materials between clean and non-clean areas, sterilising items during transfer.
An ozone generator based fumigation chamber used to disinfect instruments, tools and laboratory ware without chemicals, with ozone destruction before opening.
A portable electric vaporiser that heats formalin and releases vapour for fumigation of rooms, laminar flow cabinets and small chambers in laboratories and hospitals.
A gas-tight fumigation chamber for treating grain, seed and herbarium specimens against insect pests, used in agricultural and food research laboratories.
| Function | Products | What to confirm |
|---|---|---|
| Cabinet fumigation of instruments and samples | Fumigation Chamber, Formaldehyde Fumigation Cabinet, Ozone Fumigation Chamber for Laboratory | Chamber volume, door gasket, fumigant type, cycle timer and how residual gas is exhausted or neutralised. |
| Clean room transfer | Fumigation Pass Box with UV and Interlock | Interlock logic, UV lamp rating, internal dimensions and wall material for cleanroom panel fitting. |
| Room and bulk treatment | Portable Formalin Fumigator Vaporiser, Stored Grain Insect Fumigation Chamber | Vaporiser capacity and room volume covered, or chamber size, gas tightness and fumigant compatibility for grain. |
Clean air equipment keeps particles out by filtering air through HEPA filters, giving continuous protection while work is done. Fumigation is a periodic disinfection step: a gas such as formaldehyde or ozone is released into a closed chamber or room to kill microbes and insects, then removed. Sterile labs use both, filtered air for daily work and fumigation for instruments or room decontamination.
See also: Clean Air Equipments
The complete Laboratory Fumigation Chamber range (6 products), in alphabetical order:
Choose the fumigant and what is being treated, then check chamber volume, gas-tight door sealing, timer and heating arrangement. Confirm material of construction (stainless steel resists formalin), exhaust or neutralising unit, interlocks, warning lamps and the supply. Review local safety rules for formaldehyde and ozone exposure limits.
Formaldehyde is a proven disinfectant for rooms and cabinets but needs ventilation and neutralisation due to toxicity. Ozone leaves no chemical residue and breaks down to oxygen, but is corrosive to some materials and needs a sealed chamber and a monitored cycle. Pick based on the materials treated and the safety facilities.
Microbiology and tissue culture labs, pharma and biotechnology units, hospitals and diagnostic centres, agriculture and seed testing labs, museums with herbarium collections and food testing labs buy fumigation chambers. They are usually ordered alongside clean air benches and autoclaves when building a sterile suite.
It is effective but toxic, so fumigation should run in sealed chambers or unoccupied rooms, followed by ventilation or neutralisation, usually with ammonia. Follow your institute safety protocol and exposure limits.
A gas-tight stored grain insect fumigation chamber is designed for grain, seed and herbarium specimens. State the fumigant you will use and the batch weight so the chamber volume is right.
A pass box moves materials between areas of different cleanliness without opening both doors at once. The interlock and UV lamp keep the clean side protected in microbiology and pharma rooms.
It vaporises formalin solution to disinfect a room or cabinet before use, after which the space is sealed for a contact time and then ventilated. Room volume decides the quantity needed.
Yes, we ship fumigation chambers and pass boxes nationwide and abroad, with voltage, door gasket details and packing noted in the quotation. State the chamber volume and fumigant so the right model is quoted.
Civil Mechanical India is one of the leading manufacturers and suppliers in India for tender requirements, covering civil laboratory and industrial testing tenders and the bulk and OEM supply of mechanical engineering and testing laboratory equipment. Kindly share your tender specifications and we shall submit a complete quotation for Laboratory Fumigation Chamber.
Send us your equipment list or tender specification. We quote against IS, BS, EN, ASTM and AASHTO standards and ship to 90+ countries.