export@civilmechanicalindia.com Exporting to 90+ countries IS · BS · EN · ASTM · AASHTO

Biosafety Cabinet Manufacturers and Suppliers in India

Bio Safety Cabinet

Quick answer: A biosafety cabinet protects the operator, the sample and the environment when handling infectious or hazardous biological material through HEPA filtered airflow. Civil Mechanical India manufactures and supplies Class I, Class II A2, Class II B2 and Class III cabinets in India for microbiology, diagnostic and research labs.

Choosing among biosafety cabinet manufacturers in India starts with the containment class your work demands. Civil Mechanical India is one of the suppliers in India offering open front Class I units, recirculating Class II A2 cabinets, total exhaust B2 models and gas-tight Class III glove boxes.

The range runs in order of containment. Class I draws room air inward past the operator and exhausts it through a filter, protecting the user but not the sample. Class II cabinets add HEPA filtered laminar downflow over the work surface, with the A2 type recirculating part of the air and the B2 type exhausting everything outside the room.

Class III is a sealed glove box with attached rubber gloves for the highest risk agents. Standard biological safety cabinets with re-circulation arrangements are also listed. Typical widths are around 4 feet, with a UV lamp, fluorescent light, blower with speed control and pressure gauge on most models.

Last updated: November 2026

Class I Biosafety Cabinet Open Front

Product code: CMI-NP-0011
Buy Class I Biosafety Cabinet Open Front from India

A Class I open front biosafety cabinet that draws room air inward past the operator and exhausts it through a HEPA filter, protecting the user when handling low to moderate risk agents.

Class II Type A2 Biosafety Cabinet 4 Feet

Product code: CMI-NP-0012
Buy Class II Type A2 Biosafety Cabinet 4 Feet from India

A Class II Type A2 biological safety cabinet with HEPA filtered laminar downflow and inward airflow, protecting operator, sample and environment in microbiology and tissue culture work.

Class II Type B2 Total Exhaust Biosafety Cabinet

Product code: CMI-NP-0013
Buy Class II Type B2 Total Exhaust Biosafety Cabinet from India

A Class II Type B2 total exhaust biosafety cabinet that ducts all air outside, designed for work with volatile toxic chemicals and radionuclides along with biological agents.

Class III Glove Box Biosafety Cabinet

Product code: CMI-NP-0014
Buy Class III Glove Box Biosafety Cabinet from India

A gas-tight Class III biosafety glove box with attached rubber gloves, HEPA filtered supply and exhaust, used for handling highly hazardous microorganisms in a fully enclosed workspace.

Biosafety Cabinet range by function

FunctionProductsWhat to confirm
Operator protection, basicClass I Biosafety Cabinet Open FrontFace velocity, filter type and size, exhaust connection and whether the work does not require sterile product protection.
Class II for clinical and research workBiological Safety Cabinet, Class II Type A2 Biosafety Cabinet 4 Feet, Bio Safe Biological Safety CabinetWorking width, HEPA filter efficiency, downflow and inflow velocity, airflow alarm, UV lamp and stand or bench mounting.
Total exhaust and maximum containmentClass II Type B2 Total Exhaust Biosafety Cabinet, Class III Glove Box Biosafety CabinetDucting and exhaust blower requirement, glove ports, pass box and airlock, room ceiling height and standard to be met.

How is Biosafety Cabinet different from Clean Air Benches?

A clean air bench blows HEPA filtered air across the work area to protect the sample, but the air flows toward the operator, so it is unsafe for infectious or hazardous material. A biosafety cabinet controls airflow so that contaminated air is drawn in and filtered, protecting the operator as well. Use a clean bench for media preparation and a biosafety cabinet for pathogens, cell culture and toxic samples.

See also: Clean Air Benches

Full Biosafety Cabinet product list

The complete Biosafety Cabinet range (6 products), in alphabetical order:

Specifications and standards

What should be checked before ordering a biosafety cabinet?

Identify the biosafety level and agents you handle, since that decides Class I, II or III. Check the HEPA filter grade, airflow velocities, alarms, work area width, material of construction (stainless steel inner) and whether the exhaust can be ducted outside. Ask about certification testing at installation and filter replacement cost.

Class II A2 or B2, which is right?

A2 recirculates about 70 percent of the air and exhausts the remainder through HEPA filters, suiting most clinical and microbiology work with no volatile toxic chemicals. B2 exhausts all air outside, which is needed when working with volatile hazardous chemicals or radionuclides. B2 needs ducting and a higher running cost.

Who buys Biosafety Cabinet?

Microbiology and virology labs, diagnostic centres, hospitals, medical and veterinary colleges, biotechnology research institutes and pharma quality control units buy biosafety cabinets. They are installed with autoclaves, CO2 incubators and centrifuges, and tenders usually specify class, width, filter efficiency and local after-sales support.

Related ranges

Frequently asked questions

What is the difference between Class I, II and III cabinets?

Class I protects the operator only, Class II protects operator, sample and environment through HEPA filtered downflow, and Class III is a sealed glove box for the most dangerous agents. The agents and procedures you handle decide the class.

Does the cabinet need annual testing?

Yes, airflow velocity and filter integrity are checked on installation, at regular intervals and after any move. Ask for installation testing and service support when ordering, and plan filter replacement cost over the cabinet life.

Is a UV lamp enough for decontamination?

UV is only an aid for surface decontamination and does not replace chemical disinfection. Always wipe surfaces before and after work and follow your institute biosafety protocol; UV tubes also lose output with age and need replacement.

Can a biosafety cabinet be used with a Bunsen burner?

Open flames disturb laminar airflow and can damage the HEPA filter, so they should be avoided inside the cabinet. Use a micro incinerator or disposable loops, and keep clear of the front grille.

Do you supply cabinets for tenders and export orders?

We quote biosafety cabinets for institutional tenders in India and for overseas buyers. Provide class, size, target voltage and frequency so that packing and documentation can be confirmed with the quotation.

Tender enquiries

Request a tender quotation

We are leading manufacturers and suppliers for tender requirements from India, serving civil laboratory and industrial testing tenders and supplying mechanical engineering and testing laboratory equipment in bulk and on OEM terms. Send us your tender specifications, and a complete quotation for Biosafety Cabinet will be prepared accordingly.

  • Civil laboratory & industrial testing tenders
  • Mechanical engineering & testing lab equipment
  • Bulk and OEM supply
Send Tender Specifications Quotation prepared against your tender specifications
Get a quotation

Planning a civil engineering laboratory or replying to a tender?

Send us your equipment list or tender specification. We quote against IS, BS, EN, ASTM and AASHTO standards and ship to 90+ countries.