COD Digester Thermoreactor
Product code: CIVIL-COD-198-0001Buy COD Digester Thermoreactor from India
COD Digester Thermoreactor
Civil and environmental engineering colleges and public health labs asking for COD analysis equipment manufacturers in India often need more than a digester, so this page groups the full test chain. Civil Mechanical India is among the suppliers in India who can supply digestion, reading and reagent items together.
Digestion units include the COD thermoreactor, a 30 vial ceramic or aluminium block digester and a combined COD and TKN digestion unit that also covers nitrogen work. For field and classroom use there is a COD test kit with premixed digestion reagents and vials. Reading the result is done with a digital COD photometer that has preset programmes and filters, or by titration after reflux.
The six place COD reflux digestion apparatus with heating mantles, round bottom flasks and condensers follows the classical open reflux method and is common in teaching syllabi. Buyers select by method, sample throughput and whether results are read colorimetrically or by titration.
Last updated: November 2026
COD Digester Thermoreactor
A field and classroom COD test kit with premixed digestion reagents, vials and colour reference for estimating chemical oxygen demand in water and wastewater samples.
A combined digestion unit with heating block for both COD digestion and Kjeldahl nitrogen digestion, used in universities and quality control laboratories for water and food analysis.
A 30 vial COD digester with ceramic or aluminium heating block, digital control and safety lid for batch digestion of effluent samples in environmental testing laboratories.
A digital photometer with preset COD programmes and filters for reading digested COD vials directly in mg/L, used for quick effluent and drinking water laboratory checks.
A six place open reflux COD apparatus with heating mantles, round bottom flasks and water cooled condensers for the standard dichromate reflux method of chemical oxygen demand determination.
| Function | Products | What to confirm |
|---|---|---|
| Closed vial digestion | COD Digester Thermoreactor, Ceramic Block COD Digester 30 Vials, COD and TKN Combined Digestion Unit | Block capacity and vial type, maximum temperature, timer, and whether a nitrogen digestion block is also needed. |
| Reading and field kits | Digital COD Photometer for Water Analysis, COD Test Kit for Water and Wastewater | Measuring range in mg/L, wavelength or filters, reagent shelf life and the number of tests in each kit. |
| Classical open reflux | Six Place COD Reflux Digestion Apparatus | Number of places, mantle capacity, flask and condenser glass size, cooling water supply and fume extraction. |
The COD Digester page covers the heating block itself in several sizes and styles. This category is broader and organised around the whole test: digestion, photometric reading, field test kits and the open reflux set used for the titrimetric method. A lab that already owns a digester would mainly browse here for a photometer, reagents or kits, while a new lab can choose a complete method set.
See also: COD Digester
The complete COD Analysis Equipment range (6 products), in alphabetical order:
First fix the method: closed reflux with photometer reading, titration, or the open reflux set. Then confirm the sample range, since high strength effluent needs dilution or a high range kit. Check block positions, temperature, photometer wavelength, reagent supply and disposal of mercury or chromium waste, and ask whether calibration standards are provided.
A COD photometer reads results in minutes and suits routine volumes with preset programmes. Titration after digestion needs only glassware and standard solutions, so it costs less and works well for teaching or occasional testing. Labs reporting to authorities usually prefer the photometer for repeatability.
Civil and environmental engineering colleges, public health engineering labs, sewage and effluent treatment plant operators, industrial pollution testing labs and polytechnics buy this equipment. In an order it goes with BOD incubators, turbidity and pH meters, jar test apparatus and general glassware, which is why many buyers request a combined water testing laboratory package.
The digester blocks and photometer support closed reflux with colourimetric reading, and the six place apparatus supports the open reflux dichromate method with titration. Tell us the standard method your lab follows.
Yes, the kit uses premixed digestion reagents and vials so water samples can be tested at a site or in a classroom without a full lab. A heating block is still needed for the digestion step.
Reagent kits and vials can be quoted with the equipment. Because reagents have shelf lives and disposal rules for mercury and chromium waste, mention the annual number of tests so that a suitable quantity is suggested.
It has one heating block that serves both COD vials and Kjeldahl nitrogen tubes, which helps university and quality control labs avoid buying two digesters. Check that the block temperature reaches Kjeldahl needs.
Send the specification or destination and we will quote item wise with voltage and packing details. We supply tender buyers across India and overseas customers.
As established manufacturers and suppliers for tender requirements from India, we undertake civil laboratory and industrial testing tenders as well as bulk and OEM supply of mechanical engineering and testing laboratory equipment. Please forward your tender specifications and our team will prepare a detailed quotation for COD Analysis Equipment.
Send us your equipment list or tender specification. We quote against IS, BS, EN, ASTM and AASHTO standards and ship to 90+ countries.