Low and Middle Voltage Simulation Training System
Product code: CIVIL-LMV-81-0001Buy Low and Middle Voltage Simulation Training System from India
Low and Middle Voltage Simulation Training System
Power system and electrical safety instructors looking for Low and Middle Voltage Simulation Training System manufacturers in India want to teach switchgear behaviour without exposing students to high voltage. Civil Mechanical India builds simulation trainers for protection and distribution, and sits among the suppliers in India offering a modular power supply based system.
The main system has a control power supply, modular supply, device adapter module and electrical instruments, which students configure into protection and distribution schemes. Specific trainers add depth. The earth leakage unit uses RCCB, ELCB and an earth electrode simulation to demonstrate residual current tripping and earth resistance. The distribution board simulator has an MCCB, MCBs and meters for feeder protection, load distribution and fault operation.
Medium voltage is shown on a mimic panel of a ring main unit with vacuum breaker, isolator and earthing switch, operated using safe low voltage signals. The motor protection system teaches overload, earth fault and phase failure relays, and the power factor trainer uses an inductive load, capacitor bank and automatic controller. Check trip current ratings, relay settings range and supply voltage.
Last updated: November 2026
Low and Middle Voltage Simulation Training System
Unit with RCCB, ELCB and earth electrode simulation to demonstrate residual current tripping, earth resistance and safety of low voltage installations. Key highlights include rCCB and ELCB operation and adjustable leakage current.
Trainer simulating a low-voltage distribution board with MCCB, MCBs and meters for teaching feeder protection, load distribution and fault operation. Key highlights include mCCB and MCB feeders and metering and indicator lamps.
Mimic panel simulating a medium voltage ring main unit with vacuum breaker, isolator and earthing switch operation using safe low voltage signals. Key highlights include breaker and isolator mimic and interlock sequence training.
System with overload, earth fault and phase failure relays and starters to demonstrate motor protection settings and trip behaviour at low voltage. Key highlights include overload and earth fault relay and phase failure and unbalance protection.
Trainer with a variable inductive load, capacitor bank and automatic power factor controller to demonstrate reactive power compensation at low voltage. Key highlights include variable inductive load and capacitor steps.
| Function | Products | What to confirm |
|---|---|---|
| Earth leakage protection | Earth Leakage and RCD Protection Training Unit | RCCB sensitivity and the earth electrode simulation |
| LV distribution | Low Voltage Distribution Board Simulation Trainer | breaker ratings and the busbar layout |
| MV switchgear | Medium Voltage Switchgear Simulation Training Panel | ring main unit mimic and the interlocks |
| Motor protection and PF | Motor Protection Relay and Starter Simulation Training System, Power Factor Correction and Capacitor Bank Simulation Trainer | relay types, capacitor steps and the load |
Electrical safety training sets focus on protective behaviour and hazards: earthing, shock protection, isolation and lock-out practice. The low and middle voltage simulation system focuses on how the distribution equipment itself behaves: breakers, relays, switchgear, motor protection and power factor correction. Many institutes buy safety sets for first-year electricians, and the simulation system for power engineering and substation courses.
See also: Electrical Safety Training Sets
The complete Low and Middle Voltage Simulation Training System range (6 products), in alphabetical order:
Check the rated currents of MCBs, MCCB and RCCB, the adjustable range of the protection relays, the metering provided and whether faults are created by switches or real overloads. For the medium voltage mimic panel, confirm that operation sequences and interlocks match the type of ring main unit you teach. Supply is normally single or three phase at low voltage.
The unit simulates leakage current so students see an RCCB or ELCB trip at its rated residual current, and measure earth electrode resistance with a simulated earth. Ask for the rated tripping current (such as 30 mA for personal protection), the test button and the earth resistance range.
With a variable inductive load, a capacitor bank and an automatic power factor controller, students see lagging power factor, switch capacitor steps and watch kVAr compensation. It links to tariff penalties for low power factor in Indian industry. Check the capacitor step sizes and the controller's display and set-point range.
Polytechnic and engineering college electrical power departments, ITIs for electrician and lineman trades, utility training institutes and industrial safety academies buy these trainers. Substation training centres choose the ring main unit mimic and motor protection trainers. Typically a lab buys the distribution board, RCD and power factor trainers first, and adds medium voltage mimic panels for advanced courses.
The panel simulates a ring main unit with vacuum breaker, isolator and earthing switch using safe low voltage signals, so students practise switching sequences without exposure to medium voltage.
Overload, earth fault and phase failure relays and starters, so students set protection thresholds and watch trip behaviour at low voltage. Relay setting ranges can be checked in the manual before you order.
The trainer simulates a low-voltage distribution board with an MCCB, MCBs and meters for teaching feeder protection, load distribution and fault operation. Ask for the breaking capacity of each device.
A main control power supply, a modular power supply, a device adapter module and electrical instruments, so protection schemes can be assembled from modules. Ask for the full instrument list.
Yes, export orders are accepted. State your voltage and frequency standards so relays, MCBs and meters are specified to match local practice. Packing is prepared for sea or air freight.
Civil Mechanical India is one of the leading manufacturers and suppliers in India for tender requirements, covering civil laboratory and industrial testing tenders and the bulk and OEM supply of mechanical engineering and testing laboratory equipment. Kindly share your tender specifications and we shall submit a complete quotation for Low and Middle Voltage Simulation Training System.
Send us your equipment list or tender specification. We quote against IS, BS, EN, ASTM and AASHTO standards and ship to 90+ countries.