Water Cooling Tower Test Rig

Water Cooling Tower Test Rig

Code: RLE-0005

Water Cooling Tower Test Rig.
Product Details:

   
centrifugal blower 0.25 H.P

Water Cooling Tower Test Rig. Owing to features like durability and easy installation, the offered rig is extensively used to determine cooling efficiency of cooling tower. A team of our adept professionals, with hard-earned experience manufacture the offered rig using high grade raw material. The offered rig is available with us in various sizes, designs and other related specifications.

Features:

  • Less power consumption

  • Require less maintenance

  • Sturdy construction

 Range Of Experiments:

To determine cooling efficiency of cooling tower.
  • To calculate cooling rate.

Specification:

  • Cooling tower: Tower Size: - Cross section- 0.14m(Dia) X 0.105m (Height)Approx.Made up of transparent Acrylic material.
  • Packing: - Honeycomb mesh.
  • Centrifugal blower: - 0.25 H.P.
  • Geyser to provide: - 3.5 kW capacity - 1 nos.
  • Rota meter to measure water inlet flow.
  • Orifice meter to measure airflow, orifice dia =11.5mm.
  • Dry bulb, wet bulb thermometers: - 2 sets.
  • Calibrated water outlet measuring tank, Area = 350mm X 300mm X 250 mm approx.
  • Penalized electric controls and switches.
  • Inclined U tube manometer to measure pressure head

Service Required:

  • Single phase 230 V AC, 15 Amp supply.
  • Water supply continuous 20 LPM.

Add to Cart