We manufacture environmental lab equipment in India for water utilities, pollution control agencies, industrial effluent plants and universities. The products below carry model codes, so that buyers in Africa and South America can specify a water and environmental laboratory in a tender.

Our environmental lab equipment range

ProductModel codeUse
U-V SpectrophotometerELE-0030Concentration of chemical parameters by light absorption
Digital Turbidity MeterELE-0007Turbidity of drinking and raw water
Digital Dissolved Oxygen MeterELE-0008Dissolved oxygen in rivers, lakes and effluent
BOD IncubatorELE-0009Incubation of oxygen demand samples at controlled temperature
Digital Water and Soil Testing KitELE-0006Field screening of water and soil
Micro Kjeldahl Digestion UnitELE-0022Digestion for nitrogen determination

More than 40 products, including air samplers and sound level meters, are on our Environmental Lab Equipment page.

Tests and applications

AreaParametersInstruments
Drinking waterpH, turbidity, chlorine, hardness, bacteriaMeters, colorimeter, incubator
WastewaterBOD, COD, solids, nutrientsBOD incubator, digester, oven, spectrophotometer
Surface waterDissolved oxygen, conductivity, nutrientsPortable meters, field kits
SoilpH, salinity, nitrogenpH meter, conductivity meter, digestion unit
Air and noiseParticulates, gases, sound levelSamplers, counters, sound meters

Utilities test daily to keep supply safe. Regulators test to enforce discharge limits. Industry tests effluent before release, and universities train the analysts all of them employ.

What to specify in a tender

  1. The regulation or guideline that sets your parameter list and limits.
  2. Field or laboratory use for each instrument.
  3. Sample numbers per day, which decide incubator and digester capacity.
  4. Reagents, standards and spare probes for the first year.
  5. Training and installation at site.

Planning the laboratory rooms

Divide the laboratory by type of work. Wet chemistry needs benches with sinks, a fume hood for digestion and a distilled water supply. Instrument work needs a clean, air-conditioned room with stable power. Microbiology needs its own room with an autoclave, incubator and a clean bench, kept apart from chemical work to avoid contamination.

Sampling is where many results go wrong. Budget for sample bottles, cool boxes, preservatives and depth samplers, and train the field team as carefully as the analysts. A sample that warms on a long road journey can no longer represent the river it came from.

Quality control is the last part of the plan. Laboratories that report to a regulator should run blanks, duplicates and reference standards with every batch, and keep instrument logbooks. Buying certified standards and a second set of probes with the instruments makes that discipline possible from the first month. Decide early who will maintain the equipment, and include basic maintenance in the operator training so that small faults are fixed on site.

Markets we supply in Africa and South America

Access to safe water is a priority in both regions, and new treatment plants need laboratories.

CountryNominal mains supplyUsual port of entryNote for buyers
Togo220 V, 50 HzLoméUrban water supply projects include laboratory packages for treatment plants.
Eritrea230 V, 50 HzMassawaScarce water resources make salinity and conductivity testing important.
Gabon220 V, 50 HzLibreville (Owendo)Heavy rainfall and forest catchments give coloured, soft water that needs careful treatment control.
Madagascar220 V, 50 HzToamasinaCargo arrives by sea to an island port. Combine orders to reduce freight.
Chile220 V, 50 HzSan Antonio or ValparaísoMining regions monitor water quality closely under environmental permits.
Ecuador120 V, 60 HzGuayaquilSupply is 120 V at 60 Hz. Instruments are configured to match.

Why source from us

  • Water, wastewater, soil and air instruments from one manufacturer.
  • Portable kits for field teams and bench instruments for laboratories.
  • Glassware, ovens and incubators on the same order.
  • Installation and operator training offered.

Frequently asked questions

Do you supply reagents and standards?

Tell us the parameters. We state which starter reagents ship with each instrument and which are best bought locally because of shelf life or transport rules.

Can the instruments run on unstable power?

Portable meters run on batteries. For bench instruments we recommend a stabiliser or UPS and can quote one.

Do you equip microbiology rooms?

Yes. Incubators, autoclaves and clean benches are listed in our analytical range, and they can be added to the same offer as the chemistry instruments.

Send us your tender requirements

Environmental laboratories are often funded as part of a treatment plant or a monitoring programme, with a fixed list and a fixed deadline. Send us your tender requirements and we will respond to every line with the instrument we offer, its model code and what is included with it.

We can supply the complete laboratory from India: pH, conductivity, turbidity and dissolved oxygen meters, spectrophotometers and colorimeters, BOD incubators, COD digesters, ovens, balances, distilled water stills, glassware, field kits and air and noise monitoring instruments. One order covers both the instruments and the support equipment they depend on.

Tell us the parameters you must report, the number of samples and where the laboratory is located. Send the details through our contact page. Bench meters are also listed under Electrochemistry Instruments. We prepare an itemised quotation for each tender, since reagents, probes and training vary with the scope.