Our water tank testing instruments are made for producers of rotomoulded and blow-moulded polyethylene tanks and for the standards bodies that certify them. They check the material, its protection against sunlight and the finished tank. We manufacture them in India. The model codes below are for tender buyers in Africa and South America.
Our water tank testing instruments range
| Product | Model code | Use |
|---|---|---|
| Carbon Black Content Tester for Polyethylene Tanks | CMI-IND-0171 | Carbon black content of polyethylene |
| Carbon Black Dispersion Microscope for Plastic Tank Material | CMI-IND-0172 | Carbon black dispersion under a microscope |
| Density Gradient Column for Polyethylene Tank Samples | CMI-IND-0173 | Density of polyethylene samples |
| Dumbbell Specimen Cutting Press for Polyethylene Sheets | CMI-IND-0174 | Cutting dumbbell specimens for tensile tests |
| Fluorescent UV Weathering Chamber for Tank Materials | CMI-IND-0175 | Accelerated weathering under fluorescent UV |
| Hydrostatic Leak Test Stand for Water Storage Tanks | CMI-IND-0176 | Leak test of finished tanks under water head |
Ten instruments are shown on our Water Storage Tanks Testing Instruments page.
Tests and applications
| Requirement | Test | Why it matters |
|---|---|---|
| UV protection | Carbon black content and dispersion | Tanks stand in full sun for years |
| Correct resin | Density, melt flow | Stiffness and toughness |
| Wall strength | Tensile on cut specimens | Resistance to bulging and impact |
| Weathering | UV chamber exposure | Service life |
| Watertightness | Hydrostatic leak test | No leaks at fittings or seams |
Rooftop tanks face intense sunlight every day. Carbon black, well dispersed at the right content, protects polyethylene from ultraviolet damage. Too little and the tank becomes brittle and cracks. Poor dispersion leaves weak spots even when the content is correct.
Wall thickness and material quality decide whether a full tank keeps its shape. Standards for water tanks therefore set minimum thickness, density and strength, and many governments require certification before tanks are sold or used in public projects.
Coloured and multilayer tanks use other stabilisers, and weathering tests show whether they perform. A leak test on each tank, or on samples from each batch, is the final check.
What to specify in a tender
- The tank standard followed in your country.
- Tank sizes, to size the leak test stand.
- Furnace or other method for carbon black content.
- UV lamp type and exposure cycles.
- Thickness gauges for finished tanks.
Quality control in a tank factory
Start with powder. Check each resin lot for melt flow and density, and check pigmented powder for carbon black content before moulding. A mistake at this stage affects every tank made from the lot.
After moulding, measure wall thickness at marked points on every tank, using an ultrasonic gauge so the tank is not damaged. Cut specimens from sample tanks for tensile and dispersion tests on a schedule agreed with your certifier.
Leak test with fittings installed, since leaks usually occur at connections. Keep a record for each tank number, with date, mould and operator. When a complaint arrives, that record shows in minutes whether the tank met its specification on the day it was made.
Markets we supply in Africa and South America
Household and community water storage is essential where supply is intermittent, which describes much of both regions.
| Country | Nominal mains supply | Usual port of entry | Note for buyers |
|---|---|---|---|
| Senegal | 230 V, 50 Hz | Dakar | Urban households store water in rooftop tanks, and local production is growing. |
| Egypt | 220 V, 50 Hz | Alexandria | Very high sunlight levels make UV protection the key quality issue. |
| Tanzania | 230 V, 50 Hz | Dar es Salaam | Rural water projects specify certified tanks in public tenders. |
| Angola | 220 V, 50 Hz | Luanda | Tank producers serve fast-growing cities with intermittent supply. |
| Paraguay | 220 V, 50 Hz | River route to Asunción | Rural and peri-urban households depend on stored water. |
| Venezuela | 120 V, 60 Hz | La Guaira or Puerto Cabello | Supply is 120 V at 60 Hz. Furnaces and chambers are built to match. |
Why source from us
- Material, weathering and finished tank testers from one manufacturer.
- Instruments matched to the tank standard you name.
- General polymer testers on the same order.
- Installation and training available.
Frequently asked questions
Do you supply thickness gauges for tank walls?
Yes. Ultrasonic thickness gauges are listed in related categories. Mention tank wall thickness in your enquiry.
Can the UV chamber test coloured tanks?
Yes. Tell us the exposure cycle your standard specifies.
Are melt flow and impact testers available?
Yes. See our Rigid Plastic Testing Equipments range.
Send us your tender requirements
Tank makers seeking certification, and standards bodies equipping a test laboratory, usually work from a published standard. Send us your tender requirements with the standard named, and we will reply to each line with the instrument we offer, its model code and what is included.
We can supply the complete tank laboratory from India: carbon black content and dispersion testers, density columns and balances, melt flow testers, specimen cutting presses, tensile machines, UV weathering chambers, ultrasonic thickness gauges, impact testers and hydrostatic leak test stands. Ovens and balances are added so the laboratory is self-sufficient.
Tell us the tank sizes you produce, the standard you follow and the destination. Write to us through the contact page. We send an itemised quotation with delivery time. Test stands are sized for your tanks, so every tender is quoted individually and each instrument appears as its own line with what is supplied alongside it.