Our water tank testing instruments are made for producers of rotomoulded and blow-moulded polyethylene tanks and for the standards bodies that certify them. They check the material, its protection against sunlight and the finished tank. We manufacture them in India. The model codes below are for tender buyers in Africa and South America.

Our water tank testing instruments range

ProductModel codeUse
Carbon Black Content Tester for Polyethylene TanksCMI-IND-0171Carbon black content of polyethylene
Carbon Black Dispersion Microscope for Plastic Tank MaterialCMI-IND-0172Carbon black dispersion under a microscope
Density Gradient Column for Polyethylene Tank SamplesCMI-IND-0173Density of polyethylene samples
Dumbbell Specimen Cutting Press for Polyethylene SheetsCMI-IND-0174Cutting dumbbell specimens for tensile tests
Fluorescent UV Weathering Chamber for Tank MaterialsCMI-IND-0175Accelerated weathering under fluorescent UV
Hydrostatic Leak Test Stand for Water Storage TanksCMI-IND-0176Leak test of finished tanks under water head

Ten instruments are shown on our Water Storage Tanks Testing Instruments page.

Tests and applications

RequirementTestWhy it matters
UV protectionCarbon black content and dispersionTanks stand in full sun for years
Correct resinDensity, melt flowStiffness and toughness
Wall strengthTensile on cut specimensResistance to bulging and impact
WeatheringUV chamber exposureService life
WatertightnessHydrostatic leak testNo leaks at fittings or seams

Rooftop tanks face intense sunlight every day. Carbon black, well dispersed at the right content, protects polyethylene from ultraviolet damage. Too little and the tank becomes brittle and cracks. Poor dispersion leaves weak spots even when the content is correct.

Wall thickness and material quality decide whether a full tank keeps its shape. Standards for water tanks therefore set minimum thickness, density and strength, and many governments require certification before tanks are sold or used in public projects.

Coloured and multilayer tanks use other stabilisers, and weathering tests show whether they perform. A leak test on each tank, or on samples from each batch, is the final check.

What to specify in a tender

  1. The tank standard followed in your country.
  2. Tank sizes, to size the leak test stand.
  3. Furnace or other method for carbon black content.
  4. UV lamp type and exposure cycles.
  5. Thickness gauges for finished tanks.

Quality control in a tank factory

Start with powder. Check each resin lot for melt flow and density, and check pigmented powder for carbon black content before moulding. A mistake at this stage affects every tank made from the lot.

After moulding, measure wall thickness at marked points on every tank, using an ultrasonic gauge so the tank is not damaged. Cut specimens from sample tanks for tensile and dispersion tests on a schedule agreed with your certifier.

Leak test with fittings installed, since leaks usually occur at connections. Keep a record for each tank number, with date, mould and operator. When a complaint arrives, that record shows in minutes whether the tank met its specification on the day it was made.

Markets we supply in Africa and South America

Household and community water storage is essential where supply is intermittent, which describes much of both regions.

CountryNominal mains supplyUsual port of entryNote for buyers
Senegal230 V, 50 HzDakarUrban households store water in rooftop tanks, and local production is growing.
Egypt220 V, 50 HzAlexandriaVery high sunlight levels make UV protection the key quality issue.
Tanzania230 V, 50 HzDar es SalaamRural water projects specify certified tanks in public tenders.
Angola220 V, 50 HzLuandaTank producers serve fast-growing cities with intermittent supply.
Paraguay220 V, 50 HzRiver route to AsunciónRural and peri-urban households depend on stored water.
Venezuela120 V, 60 HzLa Guaira or Puerto CabelloSupply is 120 V at 60 Hz. Furnaces and chambers are built to match.

Why source from us

  • Material, weathering and finished tank testers from one manufacturer.
  • Instruments matched to the tank standard you name.
  • General polymer testers on the same order.
  • Installation and training available.

Frequently asked questions

Do you supply thickness gauges for tank walls?

Yes. Ultrasonic thickness gauges are listed in related categories. Mention tank wall thickness in your enquiry.

Can the UV chamber test coloured tanks?

Yes. Tell us the exposure cycle your standard specifies.

Are melt flow and impact testers available?

Yes. See our Rigid Plastic Testing Equipments range.

Send us your tender requirements

Tank makers seeking certification, and standards bodies equipping a test laboratory, usually work from a published standard. Send us your tender requirements with the standard named, and we will reply to each line with the instrument we offer, its model code and what is included.

We can supply the complete tank laboratory from India: carbon black content and dispersion testers, density columns and balances, melt flow testers, specimen cutting presses, tensile machines, UV weathering chambers, ultrasonic thickness gauges, impact testers and hydrostatic leak test stands. Ovens and balances are added so the laboratory is self-sufficient.

Tell us the tank sizes you produce, the standard you follow and the destination. Write to us through the contact page. We send an itemised quotation with delivery time. Test stands are sized for your tanks, so every tender is quoted individually and each instrument appears as its own line with what is supplied alongside it.