We manufacture electrical testing instruments in India for makers of switches, sockets, luminaires, appliances and enclosures, and for the standards bodies that certify them. Electrical safety standards rest on a set of physical tests for fire, ingress and mechanical endurance. The model codes below are for tender buyers in Africa and South America.

Our electrical testing instruments range

ProductModel codeUse
Glow Wire Flammability Test Apparatus for Electrical ProductsCMI-IND-0434Resistance of plastic parts to a glowing wire
IP Ingress Protection Dust Chamber for EnclosuresCMI-IND-0435Dust ingress protection of enclosures
IPX Rain and Water Jet Test Chamber for EnclosuresCMI-IND-0436Protection against rain and water jets
Flexible Cord Flexing Endurance Test Machine for Appliance CablesCMI-IND-0433Flexing endurance of appliance cords
Electrical Cable Hot Set and Ageing Test OvenCMI-IND-0432Hot set and ageing of cable insulation
Cable Insulation Tensile and Elongation Tester for WiresCMI-IND-0431Tensile strength and elongation of wire insulation

Ten instruments are shown on our Electronics and Electrical Testing Instruments page.

Tests and applications

HazardTestProducts
Fire from overheated partsGlow wire, needle flameSwitches, sockets, connectors
Dust and water enteringIP testsEnclosures, luminaires, meters
Broken conductorsCord flexingAppliance and tool cords
Insulation failureAgeing, tensile, hot setWires and cables
ShockFinger and probe accessAll mains products

Substandard electrical accessories cause fires and shocks. Many governments now require certification of sockets, switches, extension leads and lamps before sale, and national laboratories are being equipped to test them.

IP ratings appear on every outdoor luminaire, meter box and solar component. A dust chamber and a water spray chamber let a manufacturer verify the rating before printing it on the product.

Local assembly of fans, lamps, meters and solar products is increasing, and each assembler needs to show compliance to win utility and government contracts.

What to specify in a tender

  1. Products to be tested and their sizes.
  2. Safety standards, usually IEC or national equivalents.
  3. IP codes to be verified, which decide nozzles and chambers.
  4. Glow wire temperature range and specimen holders.
  5. Calibration accessories and reference thermocouples.

Setting up an electrical safety laboratory

Group tests by hazard. Fire tests need a dark, draught-free cabinet with fume extraction. Water tests need a wet room with drainage, a pump and a turntable. Dust chambers need a sealed enclosure and a vacuum connection to the sample.

Mechanical endurance tests run for thousands of cycles and should have counters and automatic stops. Keep electrical measuring instruments in a dry, temperature-stable area with a stabilised supply.

Standards are specific about specimen conditioning and mounting. Build simple jigs for the products you test most, and photograph each setup for the test report. Maintain a calibration schedule for thermocouples, timers and flow meters, since auditors check these first.

Train staff in safe working with mains voltage and hot surfaces, and provide isolation transformers and emergency stops at each test station.

Markets we supply in Africa and South America

Electrification, solar deployment and consumer demand are increasing the volume of electrical goods sold in both regions.

CountryNominal mains supplyUsual port of entryNote for buyers
Nigeria230 V, 50 HzLagos (Apapa or Tin Can Island)A very large market where the standards body screens imported accessories.
Algeria230 V, 50 HzAlgiersLocal appliance assembly is supported by national conformity requirements.
Kenya240 V, 50 HzMombasaSolar products and meters are tested before utility and donor procurement.
South Africa230 V, 50 HzDurbanA regulated market with compulsory specifications for many electrical goods.
Brazil127 V or 220 V, 60 Hz (varies by state)SantosCompulsory certification applies to plugs, sockets and many appliances.
Peru220 V, 60 HzCallaoMining and construction demand enclosures with verified ingress protection.

Why source from us

  • Fire, ingress, endurance and insulation testers from one manufacturer.
  • Equipment aligned with the IEC tests you name.
  • Cable testers on the same order.
  • Installation and training available.

Frequently asked questions

Which IP codes can the chambers test?

Tell us the codes you need. We confirm the nozzles, flow rates and chamber size in the offer.

Do you supply test probes and fingers?

Ask us in your enquiry. We list them with the safety test accessories.

Are cable tests covered?

Yes. See our Cable Testing Instruments range.

Send us your tender requirements

National standards bodies and manufacturers equipping a safety laboratory usually start from a list of product standards. Send us your tender requirements and we will reply to each line with the instrument we offer, its model code and the tests it covers.

We can supply from India: glow wire and flame testers, IP dust and water chambers, cord flexing machines, ageing and hot set ovens, insulation tensile testers, plug and socket endurance testers, temperature rise instruments and the measuring accessories that go with them.

Tell us the products you certify or make, the standards that apply and the destination port. Send the list through our contact page. We reply with an itemised quotation and delivery time.

The scope depends on the product range, so each tender is quoted on its own list. Laboratories planning to add products later can ask us to mark which instruments are shared between standards.