Ozone analyzer
| Product code | ELE-0020 |
| Categories | Environmental Lab Equipment |
| Standards | Manufactured to IS / BS / EN / ASTM / AASHTO as applicable |
| Supply | India and export — 90+ countries |
- Description
Ozone analyzer
1). Ambient gas monitoring and control
2). Active sampling for higher accuracy
3). Analog . Digital . Relay outputs
4). Large easy -to - read display
5). Alarm or Control options
6). Low maintenance
7). Easy to install
Applications:
1). Ambient gas control
2). Ozone generator control
3). Alarm systems
Technical Specifications:
Sensor Type : Analytical GSS Technology® Gas Sensitive Semiconductor
Ozone LOW sensor :
Range : 0 - 0.500 ppm ozone
Accuracy : <± 0.02 ppm
0 - 0.1ppm;<± 20% >0.1ppm
Max. exposure : 1 ppm
T90 response : <60 s
Sampling method : Active sampling
Operational mode : Continuous control or Alarm
Operating temperature : -5°C to 50°C
Operating relative humidity : 5% to 95% non condensing
Warm up time : 10 minutes (max. Accuracy)
Display : 3.5 digit LCD
Relay set point : User configurable
Digital output : RS232
Analog output : 0 - 5 VDC (8 bit)
Relay output (no internal alarm) : 24 V; 5A (max.)
Alarm option (no relay output) : Internal piezo 85 db @ 30cm
Power supply :
12 VDC; 800 mA;
Plug - in AC power adaptor supplied
Enclosure rating : IP20 & NEMA 1 equivalent
Enclosure dimensions : 130 W x 94 H x 57 D (mm);
Enclosure casing : Flame resistant thermoplast PS
Enclosure mounting : Screw fix
Specification
Features:1). Ambient gas monitoring and control
2). Active sampling for higher accuracy
3). Analog . Digital . Relay outputs
4). Large easy -to - read display
5). Alarm or Control options
6). Low maintenance
7). Easy to install
Applications:
1). Ambient gas control
2). Ozone generator control
3). Alarm systems
Technical Specifications:
Sensor Type : Analytical GSS Technology® Gas Sensitive Semiconductor
Ozone LOW sensor :
Range : 0 - 0.500 ppm ozone
Accuracy : <± 0.02 ppm
0 - 0.1ppm;<± 20% >0.1ppm
Max. exposure : 1 ppm
T90 response : <60 s
Sampling method : Active sampling
Operational mode : Continuous control or Alarm
Operating temperature : -5°C to 50°C
Operating relative humidity : 5% to 95% non condensing
Warm up time : 10 minutes (max. Accuracy)
Display : 3.5 digit LCD
Relay set point : User configurable
Digital output : RS232
Analog output : 0 - 5 VDC (8 bit)
Relay output (no internal alarm) : 24 V; 5A (max.)
Alarm option (no relay output) : Internal piezo 85 db @ 30cm
Power supply :
12 VDC; 800 mA;
Plug - in AC power adaptor supplied
Enclosure rating : IP20 & NEMA 1 equivalent
Enclosure dimensions : 130 W x 94 H x 57 D (mm);
Enclosure casing : Flame resistant thermoplast PS
Enclosure mounting : Screw fix
Ozone analyzer suppliers in India
Similar items you may want to view.