Thermal Shock Test Unit for Ceramic Washbasins
| Product code | CMI-IND-0560 |
| Categories | Bathware Testing Instruments |
| Standards | Manufactured to IS / BS / EN / ASTM / AASHTO as applicable |
| Supply | India and export — 90+ countries |
- Description
Dual bath thermal shock unit that alternately flushes ceramic basins and fittings with hot 93 deg C and cold 15 deg C water to check cracking. Used by sanitaryware plants to check body strength and glaze under temperature changes.
Specification
Programmable valves alternate hot and cold water on the sample for a specified number of cycles. Surface cracks and glaze defects are inspected afterward. The unit has heated and chilled tanks for continuous operation.
Features
- Hot tank 93 deg C and cold tank 15 deg C
- Solenoid valves with programmable cycle times
- Cycle counter with auto stop
- Insulated stainless steel tanks
- Drainage tray and splash guard
Technical Specifications
| Test standards | IS 2556, EN 997 thermal shock principle |
| Hot water temperature | 90 to 95 deg C |
| Cold water temperature | 15 +/-3 deg C |
| Tank volume | 60 litre each |
| Cycle time | Programmable, 1 to 10 minutes |
| Cycles | 0 to 999 |
| Chiller | 1 hp |
| Power supply | 415 V, 3 phase, 50 Hz |
Standard Accessories
- Sample fixture